| Display | :All of 0.56in character height Red 7 Segment displays a.3 Digits to display voltage 0 – 99.9V b.4 Digits to display current 0 – 999.9Amps c.6 Digits to display Amp-Hour (4 Digit) and cumulative Amp-Hour (6 Digit) |
| Max. Shunt | : Max. value of 999.9 Amps corresponding to 75mV. User programmable from front in ‘CAL’ mode. (Max. value of 9999Amps also available on request) |
| Selection of Amp Hour/Min | : Short Pin 17-18 for Amp-Hour Open link of Pin 17-18 for Amp-Minute |
| 0.1AH/Amin | : Higher 0.1 resolution by shifting internal jumper by opening cover |
| Totaliser | : 6 Digit readable in ‘Total’ Mode |
| Limit | Up to 9999 Ahr/Amin settable in limit mode using increment/decrement switches |
| Relay | : NO-P-NC of 5 Amp at 220V AC contact rating |
| Start | : Pressing front panel switch or momentarily shorting rear Pins 5 & 6 by wiring an external switch |
| Memory | :Non-volatile EEPROM solid state memory Stores programmed value of shunt, preset value, current Amp-Hr and the current Cumulative Amp-Hr to preserve current status on power failure |
| Lock | : Open Link between Pin 1 & 2 to Lock ‘Cal’ i.e. shunt value |
| Low Voltage Stop | Internally set at 10.5V for testing 12V battery. Short Pins 3 & 4 for this function |
| Supply | : 220V AC ± 10% at 50/60Hz |
| Size | : Vertical type with front panel 96 x 192 mm |
| Terminals | : At rear with marking for wiring |
| Mounting | : Panel Mounted |
| Fuse | : At rear of 0.2Amps |