In short: A USB pen-drive logger is the simplest — no software, no PC, data opens in Excel. PC-connected loggers show live trends but need a dedicated computer. Cloud logging adds remote viewing
In short: Temperature mapping places many sensors through a space at the same time to find its hot and cold spots. Use a grid covering top, middle and bottom levels, corners and the
In short: Set the clock first, select the sensor type for each input, switch off unused channels, choose a logging interval that captures your fastest meaningful change (often 1–5 min for rooms, 10–60
In short: A contact tachometer touches the shaft centre or uses a wheel on a surface — good for checking RPM and line speed. A non-contact (photo) tachometer reads reflective tape from a
In short: An on-delay timer switches once after a set time; a cyclic timer repeats ON/OFF periods continuously; a sequential timer switches several outputs one after another; a programmable digital timer lets you
In short: Use a totalising (event) counter when you only need to know how many; use a preset counter when a relay must act at a target count — cutting, batching, stopping a